ELECTRICAL
SPECIFICATIONS
Frequency Range: 25-50 kHz
Power Supply Requirements: 20-30 VDC 200 mA |
| Outputs |
0-10 VDC Linear output
Transfer Function: dB / VDC
Scale: 1 VDC = 4dB input level
Dynamic Measurement Range: 40 dB
4-20 mA DC Linear Output
Transfer Function: dB/mA DC
Scale: 1mA DC = 2.5 dB Input Level
Dynamic Measurement Range: 40 dB |
| Alarm: |
Open Collector Rated @ 24 VDC,
10 mA
Threshold Level: Adjustable over the output range. Alarm output stops conducting when input
level exceeds the threshold level (set point). |
| Heterodyned (Audio) Output |
90 dBa at full scale
output into
16 ohms
3 dB Bandwidth approx. 6kHz |
| Threshold Setting |
Low Impedance output which
senses the threshold level set point (set point) |
| Dynamic input range: |
approx. 100dB |
| I/0 cable: |
RF Shielded, Standard 3 Meters
for greater lengths consult factory |
| I/0 Connector: |
DB9 |
| Transducer Input
connector: |
BNC |
| Panel Adjustments: |
Sensitivity and threshold |
| Power Indicator: |
Blue LED |
| Alarm Indicator: |
(local) Red LED |
Enclosure:
Can be easily
mounted in standard NEMA enclosures.
Specifications subject to change without notice. |
Aluminum
Dimensions: 4.3" x 3.7" x 1.9" (LWH) 10.9 x 9.4 x 4.8 cm
Operating Temp: 32°F-140°F (0°-60° C
Weight: 13.5 oz
|
| Transducer: |
Piezo Electric, stainless steel
housing with BNC connector
Dimensions: Dia: 1.0" (2.54 cm)
Length: 2.4" (6.1 cm)
Thread (female) 10/32 |
| Warranty |
1 year parts and labor |